ENGINEERING CHANGE NOTICE ECN Number:______________3______________________ Product:_Decision 1 Chassis / Lamp_Housing_Assy' Part Number(s):____600-0024_/_400-0045-00_______ Current Board Revision Number:_____none_________ New Board Revision Number:_________none_________ Purposĺ  oć Change:__To insure that no matter what length______ screw is used to mount the lamp housing, +12 volts cannot______ be accidentally shorted to ground._____________________________ Modifications (attach additional sheets if needed): __________ The blue wire (+12V) will now be attached to the top solder____ hole and the black wire (GND) will be attached to the bottom___ solder hole as shown in figure 1.______________________________ _______________________________________________________________ APPROVED: Engineering:______________________Date__/__/__ Production:_______________________Date__/__/__ Quality Assurance_________________Date__/__/__ Customer Service__________________Date__/__/__ Purchasing________________________Date__/__/__ Marketing_________________________Date__/__/__ EFFECTIVITY: [ ] Immediate - notify current production [ ] Notify users and update stock [X] Phase in as stock is depleted Submitted by:__Bob Groppo_________________________on 10/12/83 Page_1_of_2_ DRAWINGS? __yes,_ (ASSY§, BOM and SCH) Š