APPENDIX C LOG ON INSTRUCTIONS Step 1: Set your computer's telecommunications program for full duplex using 7-bit words, even parity, and 1 stop bit, or 8-bit words, no parity, and 1 stop bit. You may call at either 300, 1200, or 2400 baud. Step 2: To reach BIX via Tymnet BIX is accessible from within the U.S., some of its territories and possessions, and major Canadian cities through local Tymnet numbers. If you don't know the Tymnet phone number(s) for your area, contact the BIX Customer Service Line (see below). At other times, numbers can be obtained by calling Tymnet at 800-336-0149. Some Tymnet callers outside the continental U.S. may be charged higher telecommunications rates. See the `bix.business' conference for details. Call your local Tymnet number. Depending on your baud rate, Tymnet will respond with "garble" or request a terminal identifier. Enter the letter A. Tymnet will ask you to log in. Enter BIX and a carriage return (CR). You will then be at the door to the BIX computer. If after you enter the letter A, your terminal is still unreadable, you must change your settings from 8 bits, 1 stop bit, no parity to 7 bits, 1 stop bit, even parity, or vice versa. Step 3: You should see the BIX welcome screen and a prompt asking you to enter your name. Respond with the BIX user name that you selected during registration. When prompted, enter your password. If you are registering, respond to the name prompt with the word new. Accessing BIX from Outside the U.S. To reach BIX from outside the U.S., you need a packet network account with your local Postal Telephone & Telegraph (PTT) company. From your PTT, enter 310690157800. Then follow instructions starting at Step 3. A list of PTT addresses and contacts for most countries is available by calling or writing BIX. (See "Problems," on page 206 for the address and telephone number of BIX.) Direct Dialing BIX has a direct-dial number in suburban Boston. The number is 617 861-9767. Enter the word BIX at the prompt. Then follow the instructions starting at Step 3. 205 BIX User Manual Problems If you follow these instructions but still are unable to log on to BIX, callers from the U.S. and Canada can telephone the BIX Customer Service Line for assistance at 1800-227-2983 between 8:30 a.m. until 11 p.m. eastern standard time (New York City time) weekdays. In New Hampshire and outside the U.S. or Canada, call 603-924-7681. The mail address is BIX, One Phoenix Mill Lane, Peterborough, NH 03458. X.25 Parameters and Overseas Users BIX supports the X.25 communications protocol according to the latest CCITT specification. Overseas users should be aware of the parameters BIX has set and adjust their PAD accordingly. To see your PAD settings as BIX understands them, from the main system prompt ( : ) enter: opt pad q This will produce a numbered list. For example: 1.1 2.1 3.126 and so on. The number on the left is the parameter; the number on the right is its value. Here are the parameters that BIX sets, their values, and an explanation: Parameter Value Explanation 1 16 DLE escape to PAD 2 1 Echo function enabled 3 126 PAD forwarding characters: Bit values (current value 2+4+8+16+32 +64=126) 1 A-Z, a-z, 0-9 2 * CR (M) 4 * ESC (^[), BEL (^G), ENQ (^E), ACK (^F) 8 * DEL, CAN (^X), DC2 (^R) 16 * ETX (^C), EOT (*D) 32 HT (^H), LF (^J), VT (^K), FF (^L) 64 All other characters less than decimal 32 and DEL 4 0 No forward on timeout 5 1 XON XOFF of Terminal 6 1 Only PAD service signals sent to user 206 BIX User Manual 7 21 Send INT packet on BREAK 8 0 PAD sends data to user's device 9 0 No PAD after CR 10 0 No line folding 11 3 Speed of User Port: 0 110 baud 1 134.5 baud 2 300 baud 3 1200 baud 4 600 baud 5 75 baud 6 150 baud 12 2400 baud 13 4800 baud 14 9600 baud 12 1 XON XOFF of PAD 13 4 PAD transmits LF to user port after echoing a CR 14 0 No PAD after LF 15 1 Line editing available 16 8 Character Delete (127 decimal=del) 17 21 Line Delete (21 decimal = ^U) 18 0 Line Display (0 decimal = nul) When you order BIX to transfer a file to you, the following adjustments are made: Parameter Value Explanation 1 0 No DLE escape to Pad 3 0 No data forwarding characters 4 1 Forward on timeout (1/20 of a second) 5 0 No flow control between PAD and user's device 7 0 No BREAK operation 9 0 No PAD after CR 10 0 No line folding 12 0 No XON XOFF of PAD 13 0 No LF insertion 14 0 No PAD after LF 15 0 No line editing When the file transfer is completed, the parameters are returned to their original settings. 207 BIX User Manual